Bobcat 331, 331E & 334
Fuse Block
![Mini Excavator Bobcat 331, 331E and 334 - Diagram of the Fuse Box](/shemy/en/uploads/posts/2024-02/fbdwiki0011708198962.webp)
No. | A | Description |
---|---|---|
1 | 5 | Wiper |
2 | 20 | Switched Power |
3 | 25 | Alternator/Power Relay |
4 | 25 | Attach. Control Device |
5 | - | Not Used |
6 | 25 | Air Cond., Heater Fan |
7 | 5 | Ignition |
8 | 25 | Fuel Solenoid |
9 | 25 | Controller |
10 | 25 | Attach. Control Device |
11 | 20 | Lights |
12 | 15 | Accessory Plug |
Relay |
||
E | Switched Power | |
F | Fuel Solenoid | |
G | Lights | |
H | Glow Plugs | |
J | Starter |
![Mini Excavator Bobcat 331, 331E and 334 - Location of the Main Fuse](/shemy/en/uploads/posts/2024-02/fbdwiki0011708198953.webp)
The excavator has a 12 volt, negative ground electrical system. The electrical system is protected by fuses located under the cover at the right side of the excavator (Item 1). The fuses will protect the electrical system when there is an electrical overload. The reason for the overload must be found before starting the engine again.